Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.855
Filtrar
1.
Microsurgery ; 44(4): e31178, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38661385

RESUMO

BACKGROUND: Transfer of the fascicle carrying the flexor carpi ulnaris (FCU) branch of the ulnar nerve (UN) to the biceps/brachialis muscle branch of the musculocutaneous nerve (Oberlin's procedure), is a mainstay technique for elbow flexion restoration in patients with upper brachial plexus injury. Despite its widespread use, there are few studies regarding the anatomic location of the donor fascicle for Oberlin's procedure. Our report aims to analyze the anatomical variability of this fascicle within the UN, while obtaining quantifiable, objective data with intraoperative neuromonitoring (IONM) for donor fascicle selection. METHODS: We performed a retrospective review of patients at our institution who underwent an Oberlin's procedure from September 2019 to July 2023. We used IONM for donor fascicle selection (greatest FCU muscle and least intrinsic hand muscle activation). We prospectively obtained demographic and electrophysiological data, as well as anatomical location of donor fascicles and post-surgical morbidities. Surgeon's perception of FCU/intrinsic muscle contraction was compared to objective muscle amplitude during IONM. RESULTS: Eight patients were included, with a mean age of 30.5 years and an injury-to-surgery interval of 4 months. Donor fascicle was located anterior in two cases, posterior in two, radial in two and ulnar in two patients. Correlation between surgeon's perception and IONM findings were consistent in six (75%) cases. No long term motor or sensory deficits were registered. CONCLUSIONS: Fascicle anatomy within the UN at the proximal arm is highly variable. The use of IONM can aid in optimizing donor fascicle selection for Oberlin's procedure.


Assuntos
Monitorização Neurofisiológica Intraoperatória , Transferência de Nervo , Nervo Ulnar , Humanos , Estudos Retrospectivos , Adulto , Masculino , Feminino , Nervo Ulnar/cirurgia , Nervo Ulnar/anatomia & histologia , Transferência de Nervo/métodos , Monitorização Neurofisiológica Intraoperatória/métodos , Plexo Braquial/anatomia & histologia , Plexo Braquial/cirurgia , Plexo Braquial/lesões , Músculo Esquelético , Adulto Jovem , Neuropatias do Plexo Braquial/cirurgia , Pessoa de Meia-Idade
2.
Med Eng Phys ; 125: 104127, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38508804

RESUMO

The monitoring of the neuromuscular blockade is critical for patient's safety during and after surgery. The monitoring of neuromuscular blockade often requires the use of Train of Four (TOF) technique. During a TOF test two electrodes are attached to the ulnar nerve, and a series of four electric pulses are applied. The electrical stimulation causes the thumb to twitch, and the amount of twitch varies depending on the amount of neuromuscular blockade in patient's system. Current medical devices used to assist anesthesiologists to perform TOF monitoring often require free hand movement and do not provide accurate or reliable results. The goal of this work is to design, prototype and test a new medical device that provides reliable TOF results when thumb movement is restricted. A medical device that uses a pressurized catheter balloon to detect the response thumb twitch of the TOF test is created. An analytical model, numerical study, and mechanical finger testing were employed to create an optimum design. The design is tested through a pilot human subjects study. No significant correlation is reported with subjects' properties, including hand size.


Assuntos
Bloqueio Neuromuscular , Fármacos Neuromusculares não Despolarizantes , Humanos , Monitoração Neuromuscular/métodos , Nervo Ulnar/fisiologia , Estimulação Elétrica
3.
J Pediatr Orthop ; 44(5): e426-e432, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38454784

RESUMO

OBJECTIVE: This work aimed to evaluate the results of using a 2-stage surgical treatment strategy without doing anterior transposition of the ulnar nerve (ATUN) for cases with long-standing nonunited fracture lateral humeral condyle (LHC) in children, accompanied by a critical review. METHODS: A consecutive 12 children with a long-standing ">2 years" nonunited LHC with evident radiologic gross anatomic distortion of the elbow were included in this study. A 2-stage surgical treatment strategy was applied, wherein the first stage, open functional reduction, osteosynthesis, and iliac bone graft were done. Then after 6 months, the second stage surgery was carried out in the form of supracondylar humeral corrective osteotomy if the cubitus valgus angle was ≥20 degrees. ATUN was not done for any of the cases even with those having ulnar nerve dysfunction. RESULTS: Union took place in 11 out of the 12 cases after a mean follow-up period of 11 weeks (range: 8 to 14 wk; SD: 1.6). All the 7 cases showed preoperative ulnar nerve dysfunction and reported clinical recovery at the end of their follow-up. CONCLUSIONS: Two-stage surgical treatment strategy without ATUN is a convenient, reproducible, and successful line of treatment for children presented with longstanding nonunited LHC with anatomically distorted elbow. LEVEL OF EVIDENCE: Level IV-case series.


Assuntos
Articulação do Cotovelo , Fraturas não Consolidadas , Fraturas do Úmero , Criança , Humanos , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Fraturas do Úmero/complicações , Úmero/cirurgia , Nervo Ulnar , Fixação Interna de Fraturas/métodos , Fraturas não Consolidadas/cirurgia , Articulação do Cotovelo/cirurgia , Resultado do Tratamento , Amplitude de Movimento Articular/fisiologia , Estudos Retrospectivos
4.
Sci Rep ; 14(1): 4643, 2024 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-38409319

RESUMO

To date, little is known about the usefulness of ultra-high frequency ultrasound (UHF-US, 50-70 MHz) in clinical practice for the diagnosis of dysimmune neuropathies. We present a prospective study aimed at comparing UHF-US alterations of nerves and fascicles in chronic inflammatory demyelinating polyradiculoneuropathy (CIDP), distal CIDP (d-CIDP) and anti-MAG neuropathy and their relationships with clinical and electrodiagnostic (EDX) features. 28 patients were included (twelve CIDP, 6 d-CIDP and 10 anti-MAG) and ten healthy controls. Each patient underwent neurological examination, EDX and UHF-US study of median and ulnar nerves bilaterally. UHF-US was reliable in differentiating immune neuropathies from controls when using mean and/or segmental nerve and/or fascicle cross-sectional area (CSA); furthermore, fascicle ratio (fascicle/nerve CSA) was a reliable factor for differentiating d-CIDP from other types of polyneuropathies. The fascicle CSA appears to be more increased in CIDP and its variant than in anti-MAG neuropathy. UHF-US offers information beyond simple nerve CSA and allows for a better characterization of the different forms of dysimmune neuropathies.


Assuntos
Polineuropatias , Polirradiculoneuropatia Desmielinizante Inflamatória Crônica , Humanos , Polirradiculoneuropatia Desmielinizante Inflamatória Crônica/diagnóstico por imagem , Estudos Prospectivos , Ultrassonografia , Nervo Ulnar/diagnóstico por imagem , Glicoproteína Associada a Mielina , Autoanticorpos , Nervos Periféricos/diagnóstico por imagem , Condução Nervosa
5.
J Hand Surg Am ; 49(4): 346-353, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38323947

RESUMO

PURPOSE: Microsuture neurorrhaphy is technically challenging and has inherent drawbacks. This study evaluated the potential of a novel, sutureless nerve coaptation device to improve efficiency and precision. METHODS: Twelve surgeons participated in this study-six attending hand/microsurgeons and six trainees (orthopedic and plastic surgery residents or hand surgery fellows). Twenty-four cadaver arm specimens were used, and nerve repairs were performed at six sites in each specimen-the median and ulnar nerves in the proximal forearm, the median and ulnar nerves in the distal forearm, and the common digital nerves to the second and third web spaces. Each study participant performed nerve repairs at all six injury locations in two different cadaver arms (n = 12 total repairs for each participating surgeon). The nerve repairs were timed, tested for tensile strength, and graded for alignment and technical repair quality. RESULTS: A substantial reduction in time was required to perform repairs with the novel coaptation device (1.6 ± 0.8 minutes) compared with microsuture (7.2 ± 3.6 minutes). Device repairs were judged clinically acceptable (scoring "Excellent" or "Good" by most of the expert panel) in 97% of the repairs; the percentage of suture repairs receiving Excellent/Good scores by most of the expert panel was 69.4% for attending surgeons and 36.1% for trainees. The device repairs exhibited a higher average peak tensile force (7.0 ± 3.6 N) compared with suture repairs (2.6 ± 1.6 N). CONCLUSIONS: Nerve repairs performed with a novel repair device were performed faster and with higher technical precision than those performed using microsutures. Device repairs had substantially greater tensile strength than microsuture repairs. CLINICAL RELEVANCE: The evaluated novel nerve repair device may improve surgical efficiency and nerve repair quality.


Assuntos
Mãos , Nervos Periféricos , Humanos , Nervos Periféricos/cirurgia , Mãos/cirurgia , Nervo Ulnar/cirurgia , Braço , Cadáver , Técnicas de Sutura
6.
Muscle Nerve ; 69(5): 543-547, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38356457

RESUMO

INTRODUCTION/AIMS: Ulnar nerve instability (UNI) in the retroepicondylar groove is described as nerve subluxation or dislocation. In this study, considering that instability may cause chronic ulnar nerve damage by increasing the friction risk, we aimed to examine the effects of UNI on nerve morphology ultrasonographically. METHODS: Asymptomatic patients with clinical suspicion of UNI were referred for further clinical and ultrasonographic examination. Based on ulnar nerve mobility on ultrasound, the patients were first divided into two groups: stable and unstable. The unstable group was further divided into two subgroups: subluxation and dislocation. The cross-sectional area (CSA) of the nerve was measured in three regions relative to the medial epicondyle (ME). RESULTS: In the ultrasonographic evaluation, UNI was identified in 59.1% (52) of the 88 elbows. UNI was bilateral in 50% (22) of the 44 patients. Mean CSA was not significantly different between groups. A statistically significant difference in ulnar nerve mobility was found between the group with CSA of <10 versus ≥10 mm2 (p = .027). Nerve instability was found in 85.7% of elbows with an ulnar nerve CSA value of ≥10 mm2 at the ME level. DISCUSSION: The probability of developing neuropathy in patients with UNI may be higher than in those with normal nerve mobility. Further prospective studies are required to elucidate whether asymptomatic individuals with UNI and increased CSA may be at risk for developing symptomatic ulnar neuropathy at the elbow.


Assuntos
Articulação do Cotovelo , Neuropatias Ulnares , Humanos , Nervo Ulnar/diagnóstico por imagem , Neuropatias Ulnares/diagnóstico por imagem , Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/inervação , Ultrassonografia
7.
Handchir Mikrochir Plast Chir ; 56(1): 101-105, 2024 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-38359863

RESUMO

INTRODUCTION: A supracondylar process is a bony spur on the distal anteromedial surface of the humerus, and it is considered an anatomical variant with a prevalence of 0.4-2.7% according to anatomical studies. In almost all cases, it is associated with a fibrous, sometimes ossified ligament, which extends from the supracondylar process to the medial epicondyle. This ligament is known in the literature as the ligament of Struthers, named after the Scottish anatomist who first described it in detail in 1854. In rare cases, the supracondylar process can be a clinically relevant finding as a cause of nerve compression syndrome. The median and ulnar nerve can be trapped by the ring-shaped structure formed by the ligament of Struthers and the supracondylar process. CASE REPORT: A 59-year-old patient with symptoms of a cubital tunnel syndrome and additional ipsilateral sensory deficits in his thumb was referred to our clinic. Electroneurography showed no signs of an additional carpal tunnel syndrome. Preoperative x-ray and CT scans of the upper arm revealed a supracondylar process, which led us to suspect an associated entrapment of the median nerve. An MRI scan of the upper arm showed a ligament of Struthers and signs of a related median nerve compression as we initially assumed. We performed a surgical decompression of the median nerve in the distal upper arm and of the ulnar nerve in the cubital tunnel. Intraoperatively, there was evidence of compression of the median nerve due to the supracondylar process and the ligament of Struthers. The latter was cleaved and then resected along with the supracondylar process. Three months after surgery, the patient had no motor or sensory deficits. SUMMARY: The ring-shaped structure formed by the supracondylar process and ligament of Struthers represents a rare cause of compression syndrome of the median and ulnar nerve. Its incidence remains unknown so far. This anatomical variant should be considered a differential diagnosis in case of possibly related nerve entrapment symptoms after ruling out other, more frequent nerve compression causes. Moreover, the supracondylar process should be completely resected including the periosteum during surgery to minimise the risk of recurrence.


Assuntos
Síndrome do Túnel Carpal , Síndromes de Compressão Nervosa , Humanos , Pessoa de Meia-Idade , Nervo Mediano/cirurgia , Ligamentos/cirurgia , Úmero/diagnóstico por imagem , Úmero/cirurgia , Úmero/inervação , Braço , Nervo Ulnar/cirurgia , Síndrome do Túnel Carpal/diagnóstico , Síndrome do Túnel Carpal/etiologia , Síndrome do Túnel Carpal/cirurgia , Síndromes de Compressão Nervosa/diagnóstico , Síndromes de Compressão Nervosa/etiologia , Síndromes de Compressão Nervosa/cirurgia
8.
Surg Radiol Anat ; 46(4): 473-482, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38329521

RESUMO

PURPOSE: Anatomical variations of the concave shaped retrocondylar ulnar groove (RUG) can contribute to ulnar nerve instability. However, there are currently limited available standardized data describing the anatomy of the RUG based on radiologic imaging, such as computed tomography (CT). This study aims to provide a comprehensive description and classification of RUG anatomy based on RUG angle measurements. METHODS: 400 CT scans of the elbows of adults showing no signs of osseous damage were evaluated. RUG angles were measured in four anatomically defined axial planes that spanned from the proximal to the distal end of the RUG. Furthermore, distance measurements at the medial epicondyle were conducted. A classification system for the RUG is proposed based on the acquired RUG angles, aiming to categorize the individual angles according to the 25th and 75th percentiles. RESULTS: RUG angles were significantly larger in males compared to females (p < 0.001) accompanied by larger distances including the off-set and height of the medial epicondyle (p < 0.001). RUG angles decreased from proximal to distal locations (p < 0.05). CONCLUSION: This study revealed that men exhibited larger RUG angles compared to women, indicating a less-concave shape of the RUG in men. Introducing an objective RUG classification system can improve our understanding of anatomical variations and potentially find application in diagnostics and preoperative planning.


Assuntos
Articulação do Cotovelo , Nervo Ulnar , Masculino , Adulto , Humanos , Feminino , Nervo Ulnar/anatomia & histologia , Articulação do Cotovelo/anatomia & histologia , Cotovelo/inervação , Tomografia Computadorizada por Raios X
9.
J Shoulder Elbow Surg ; 33(5): 1092-1103, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38286182

RESUMO

BACKGROUND: Ulnar neuropathy at the elbow caused by heterotopic ossification (HO) is a rare condition. This retrospective study aims to report on 32 consecutive cases of ulnar nerve encasement caused by elbow HO and evaluate long-term outcomes of operative management and a standardized postoperative rehabilitation regimen. METHODS: A retrospective case series was conducted on 32 elbows (27 patients) that underwent operative management of bony ulnar nerve encasement. All procedures were performed in the inpatient setting at an Academic Level 1 Trauma Center from September 1999 to July 2021 by one of 3 fellowship-trained shoulder and elbow. Postoperatively, all patients received formal physical therapy, HO prophylaxis (30 received indomethacin, 2 received radiation), and a structured continuous passive motion machine regimen. Patient demographics, age, gender, type of injury, history of tobacco use, and medical comorbidities were obtained to include in the analysis. Long-term follow-up examinations were performed to evaluate elbow flexion-extension arc of motion, Mayo Elbow Performance Score, and visual analog scale pain scores. RESULTS: Thirty-two elbows with complete bony ulnar nerve encasement secondary to HO were identified (14 from burns, 15 from trauma, 3 closed head injuries). Following surgery, the mean flexion-extension arc of motion improved significantly, increasing from 21° to 100° at long-term follow-up (average 8.7 years, range 2-17 years), with statistically significant improvements in preoperative vs. long-term postoperative elbow extension (P < .001), flexion (P < .001), and total arc of motion (P < .001). There was a statistically significant improvement in pre- vs. postprocedure ulnar nerve function, as demonstrated by a decrease in average McGowan grade (1.2-0.7; P = .002). Additionally, 63% of patients with preoperative ulnar neuropathy symptoms (20/32) had either complete resolution or subjective improvement after surgery. The mean time from injury to surgery was 518 days (range 65-943 days). Age, gender, time to surgery, and medical comorbidities were not associated with outcomes. The complication rate was 9% (3/32). Patients had an average flexion-extension arc of motion of 97° and average Mayo Elbow Performance Score of 80 ("good") at long-term follow-up. CONCLUSIONS: The combination of operative management, postoperative HO prophylaxis, and a regimented rehabilitation program has proven to be a durable solution for treating and ensuring good long-term functional outcomes for patients with elbow HO and bony ulnar nerve encasement. This treatment approach leads to superior range of motion, improved or resolved ulnar neuropathy, and good to excellent long-term functional outcomes.


Assuntos
Articulação do Cotovelo , Ossificação Heterotópica , Neuropatias Ulnares , Humanos , Cotovelo/cirurgia , Nervo Ulnar/cirurgia , Estudos Retrospectivos , Articulação do Cotovelo/cirurgia , Neuropatias Ulnares/etiologia , Ossificação Heterotópica/etiologia , Ossificação Heterotópica/cirurgia , Ossificação Heterotópica/diagnóstico , Amplitude de Movimento Articular/fisiologia , Resultado do Tratamento
10.
Bone Joint J ; 106-B(2): 212-218, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38295855

RESUMO

Aims: Medial humeral epicondyle fractures (MHEFs) are common elbow fractures in children. Open reduction should be performed in patients with MHEF who have entrapped intra-articular fragments as well as displacement. However, following open reduction, transposition of the ulnar nerve is disputed. The aim of this study is to evaluate the need for ulnar nerve exploration and transposition. Methods: This was a retrospective cohort study. The clinical data of patients who underwent surgical treatment of MHEF in our hospital from January 2015 to January 2022 were collected. The patients were allocated to either transposition or non-transposition groups. Data for sex, age, cause of fracture, duration of follow-up, Papavasiliou and Crawford classification, injury-to-surgery time, preoperative ulnar nerve symptoms, intraoperative exploration of ulnar nerve injury, surgical incision length, intraoperative blood loss, postoperative ulnar nerve symptoms, complications, persistent ulnar neuropathy, and elbow joint function were analyzed. Binary logistic regression analysis was used for statistical analysis. Results: A total of 124 patients were followed up, 50 in the ulnar nerve transposition group and 74 in the non-transposition group. There were significant differences in ulnar nerve injury (p = 0.009), incision length (p < 0.001), and blood loss (p = 0.003) between the two groups. Binary logistic regression analysis revealed that preoperative ulnar nerve symptoms (p = 0.012) were risk factors for postoperative ulnar nerve symptoms. In addition, ulnar nerve transposition did not affect the occurrence of postoperative ulnar nerve symptoms (p = 0.468). Conclusion: Ulnar nerve transposition did not improve clinical outcomes. It is recommended that the ulnar nerve should not be transposed when treating MHEF operatively.


Assuntos
Fraturas do Úmero , Nervo Ulnar , Criança , Humanos , Nervo Ulnar/cirurgia , Estudos Retrospectivos , Fraturas do Úmero/cirurgia , Cotovelo , Úmero , Resultado do Tratamento
11.
JBJS Case Connect ; 14(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38207087

RESUMO

CASES: We present 2 cases of median nerve reconstruction using distal nerve transfers after resection of unusual benign median nerve tumors. Critical sensation was restored in case 1 by transferring the fourth common digital nerve to first web digital nerves. Thumb opposition was regained by transferring the abductor digiti minimi ulnar motor nerve branch to the recurrent median motor nerve branch. Critical sensation was restored in case 2 by transferring the long finger ulnar digital nerve to the index finger radial digital nerve. CONCLUSION: Distal nerve transfers, even with short grafts, are reliable median nerve deficit treatments, sparing the need for larger autologous nerve grafts and late tendon opponensplasties.


Assuntos
Nervo Mediano , Transferência de Nervo , Humanos , Nervo Mediano/cirurgia , Dedos/cirurgia , Dedos/inervação , Nervo Ulnar/cirurgia , Nervo Radial/cirurgia
12.
J Hand Surg Eur Vol ; 49(1): 66-72, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37694818

RESUMO

Manugraphy with three different cylinder sizes was used to quantify the contribution of fingers, thumb and palm to grip force in patients with unilateral cubital tunnel syndrome. Forces in the affected and contralateral hands differed by up to 29%. Although grip force is usually maximal when gripping small handles, ulnar nerve palsy resulted in similar absolute grip forces using the 100-mm and 200-mm cylinders. The contact area between the affected hand and the cylinders was reduced by 5%-9%. We noted a high correlation between the contact area and grip force, visible atrophy and permanently impaired sensibility. The load distribution differed significantly between both hands for all cylinder sizes. When gripping large objects, the main functional impairment in cubital tunnel syndrome is weakness in positioning and stabilizing the thumb. Weak intrinsic finger muscles are responsible for loss of force when gripping small objects. Level of evidence: III.


Assuntos
Síndrome do Túnel Ulnar , Humanos , Mãos , Extremidade Superior , Dedos , Polegar , Nervo Ulnar
13.
J Ultrasound Med ; 43(1): 171-188, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37815434

RESUMO

This is the first of a two-part article in which we focus on the ultrasound (US) appearance of the normal ulnar nerve (UN) and its main branches. The detailed US anatomy of the UN course is presented with high-resolution US images obtained with the latest-generation US machines and transducers.


Assuntos
Síndrome do Túnel Ulnar , Nervo Ulnar , Humanos , Nervo Ulnar/diagnóstico por imagem , Nervo Ulnar/anatomia & histologia , Ultrassonografia
14.
Tech Hand Up Extrem Surg ; 28(1): 45-48, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37899550

RESUMO

Ulnar nerve injury initiates an imbalance between the intrinsic muscles and extrinsic extensors of the ring and small fingers, which leads to the characteristic hyperextension of the metacarpophalangeal (MP) joints and flexion of the proximal interphalangeal joints of these 2 digits-commonly referred to as the ulnar claw hand. In addition to these changes in the static posture of the hand, ulnar nerve palsy severely impairs grasp due to deficient active MP joint flexion. In most cases, motor balance can be restored by preventing MP joint hyperextension and augmenting MP joint flexion using the Zancolli lasso procedure (ZLP). Ulnar neuropathy can cause a second motor imbalance between the ulnar intrinsics and the extensor digit minimi leading to an abduction deformity of the small finger known as Wartenberg's sign. The inability to adduct the small finger can be a great source of frustration to patients. Using a cadaveric biomechanical model, we have developed a simple modification of the Zancolli lasso procedure that simultaneously corrects claw deformity and Wartenberg's sign and we report its efficacy in 2 clinical cases.


Assuntos
Deformidades Adquiridas da Mão , Neuropatias Ulnares , Humanos , Mãos , Neuropatias Ulnares/complicações , Nervo Ulnar/lesões , Força da Mão , Deformidades Adquiridas da Mão/etiologia , Dedos
15.
J Shoulder Elbow Surg ; 33(3): 550-555, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37890764

RESUMO

BACKGROUND: Radiographic and physical examination findings of ulnar nerve instability have been recognized in overhead throwing athletes, despite the fact that some of these abnormalities may be asymptomatic and represent adaptive changes. While recommendations for screening and early detection have been made that can adversely impact an athletes' career, the presence of bilateral ulnar nerve subluxation and its relationship with medial elbow symptoms has not been characterized in professional overhead throwing athletes. PURPOSE: To characterize the prevalence of bilateral ulnar nerve subluxation among professional baseball pitchers. METHODS: A cross-sectional observational analysis was conducted utilizing standardized ultrasonographic examinations of bilateral elbows in 91 consecutive professional baseball pitchers (median age, 22 years; range, 17-30 years). The relationship between ulnar nerve subluxation and ulnar nerve signs, symptoms, and provocative physical examination maneuvers was also investigated. RESULTS: The prevalence of bilateral ulnar nerve subluxation was 26.4% (95% CI, 17.7%-36.7%; 24 of the 91 athletes). Thirty-five athletes (38.5%; 95% CI, 28.4%-49.2%) had subluxation in at least 1 elbow. No athletes with subluxation had positive ulnar nerve signs, symptoms, or provocative tests. CONCLUSION: Ulnar nerve subluxation is common among professional pitchers, and is more often than not bilateral. In this population of athletes, ulnar nerve subluxation does not appear to be associated with pathological findings.


Assuntos
Beisebol , Ligamento Colateral Ulnar , Articulação do Cotovelo , Luxações Articulares , Humanos , Adulto Jovem , Adulto , Nervo Ulnar , Beisebol/fisiologia , Estudos Transversais , Prevalência , Cotovelo/diagnóstico por imagem , Cotovelo/fisiologia , Articulação do Cotovelo/diagnóstico por imagem
16.
Eur J Radiol ; 170: 111201, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38042022

RESUMO

BACKGROUND: Traditional treatment for displaced humeral supracondylar fractures (SCFs) in children involves closed reduction (CR) under fluoroscopic guidance, percutaneous pinning, and immobilization with a long-arm cast. This study aims to explore the viability of using radiation-free ultrasound (US) for guiding CR and tracking ulnar nerve dynamics during medial pinning, contrasting the US method with the conventional cross pinning technique. MATERIALS AND METHODS: We assessed 70 children with acute displaced SCFs. The US group (n = 30) underwent US-guided reduction, whereas the traditional group (n = 40) underwent fluoroscopy-guided reduction. Both groups received percutaneous cross pinning and subsequent cast immobilization. Postoperative outcomes were compared between the two methods after a 6-month follow-up. In the US group, ultrasonography assessed fracture displacement distances before and after CR. The angle at which the ulnar nerve relocated to the cubital tunnel during elbow extension was documented using real-time US monitoring during medial pinning. RESULTS: The US group demonstrated improved reduction accuracy, increased range of motion, superior restoration of both Baumann and Humeroulnar angles, and a decreased incidence of malunions compared to the traditional group (all p < 0.05). The ultrasonographic measurement of fracture displacement was comparable with that of fluoroscopy (intraclass correlation coefficient > 0.90). In the US group, no ulnar nerve injury was noted, compared to 2.5 % in the traditional group, and real-time US observations revealed ulnar nerve hypermobility, with 53.3 % of patients exhibiting anterior ulnar nerve subluxation at 120° elbow flexion, 40 % at 90°, 16.7 % at 60°, and none at 30° flexion. CONCLUSION: Ultrasound is as reliable as fluoroscopy for evaluating fracture reductions. The use of intra-operative ultrasound significantly improves reduction accuracy and radiographic outcomes while reducing the risk of ulnar nerve injury.


Assuntos
Fraturas do Úmero , Luxações Articulares , Humanos , Criança , Nervo Ulnar/diagnóstico por imagem , Pinos Ortopédicos , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Úmero , Ultrassonografia , Resultado do Tratamento , Estudos Retrospectivos , Fixação Interna de Fraturas/métodos
17.
Muscle Nerve ; 69(2): 218-221, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38009374

RESUMO

INTRODUCTION/AIMS: A common concept is that traumatic nerve injuries are more likely axonal, and that compressive neuropathies are more likely demyelinating. The purpose of this study was to compare traumatic versus non-traumatic ulnar neuropathy at the elbow (UNE) to look for electrodiagnostic differences between the two groups. METHODS: A retrospective 3 year review of UNE patients at two academic health science centers was conducted. Patients were grouped into acute traumatic UNE versus chronic non-traumatic UNE based on clinical history. Electrodiagnostic measurements were compared between the two groups. RESULTS: There were 50 subjects with acute traumatic UNE and 41 with chronic non-traumatic UNE. Mean age and sex distribution were similar but those with traumatic UNE had a 7 month duration of symptoms, while those with chronic UNE had 29 month duration (p < .001). All electrodiagnostic measurements were similar between the two groups including compound muscle action potential amplitudes, motor conduction velocities, frequency of conduction block, sensory nerve studies, and needle electromyography. DISCUSSION: We did not find a difference between the two groups. One should not make inferences regarding acuity or etiology based on electrodiagnostic features alone.


Assuntos
Cotovelo , Neuropatias Ulnares , Humanos , Cotovelo/inervação , Eletrodiagnóstico , Estudos Retrospectivos , Condução Nervosa/fisiologia , Neuropatias Ulnares/diagnóstico , Nervo Ulnar
18.
Hand Surg Rehabil ; 43(1): 101614, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37935334

RESUMO

OBJECTIVE: Recurrence after primary ulnar tunnel syndrome surgery is observed in 1.4%-25% of patients. However, the outcome of revision surgery is uncertain and limited. This study aimed to assess the clinical and functional outcomes of neurolysis combined with anterior subcutaneous transposition in cases of recurrence. PATIENTS AND METHODS: This retrospective single-center study included patients who were operated on for iterative ulnar tunnel syndrome at the elbow between January 1996 and December 2020, with a minimum follow-up of 24 months. Demographic data, pre- and post-operative clinical evaluations, surgical details, and satisfaction levels were collected. RESULTS: Twenty-eight patients were reviewed. Mean follow-up was 11.7 years (range, 2.1-26.4 years). The secondary procedure led to significant improvement in mean Quick-DASH score, from 25.3 (range, 11-50) to 20.0 (range, 11-49) (p = 0.023), with a satisfaction rate of 78.5%. Symptoms of pain (p = 0.033), amyotrophy (p = 0.013), hypoesthesia (p < 0.01), and paresthesia (p < 0.001) also showed significant improvement. There were 7 cases of failure (25.0%). CONCLUSION: The combination of neurolysis and anterior subcutaneous transposition was a reliable technique, improving clinical outcome in recurrent ulnar tunnel syndrome after previous surgery. LEVEL OF EVIDENCE: IV - retrospective study.


Assuntos
Síndrome do Túnel Ulnar , Humanos , Síndrome do Túnel Ulnar/cirurgia , Nervo Ulnar/cirurgia , Estudos Retrospectivos , Descompressão Cirúrgica/métodos , Procedimentos Neurocirúrgicos
19.
Anat Histol Embryol ; 53(1): e12972, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37715494

RESUMO

The knowledge of the morphology and morphometry of peripheral nerves is essential for developing neural interfaces and understanding nerve regeneration in basic and applied research. Currently, the most adopted animal model is the rat, even though recent studies have suggested that the neuroanatomy of large animal models is more comparable to humans. The present knowledge of the morphological structure of large animal models is limited; therefore, the present study aims to describe the morphological characteristics of the Ulnar Nerve (UN) in pigs. UN cross-sections were taken from seven Danish landrace pigs at three distinct locations: distal UN, proximal UN and at the dorsal cutaneous branch of the UN (DCBUN). The nerve diameter, fascicle diameter and number, number of fibres and fibre size were quantified. The UN diameter was larger in the proximal section compared to the distal segment and the DCBUN. The proximal branch also had a more significant number of fascicles (median: 15) than the distal (median: 10) and the DCBUN (median: 11) segments. Additionally, the mean fascicle diameter was smaller at the DCBUN (mean: 165 µm) than at the distal (mean: 197 µm) and proximal (mean: 199 µm) segments of the UN. Detailed knowledge of the microscopical structure of the UN in pigs is critical for further studies investigating neural interface designs and computational models of the peripheral nervous system.


Assuntos
Membro Anterior , Nervo Ulnar , Humanos , Ratos , Animais , Suínos , Nervo Ulnar/anatomia & histologia , Membro Anterior/inervação , Pele
20.
Neurol Res ; 46(2): 125-131, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37729085

RESUMO

BACKGROUND: The polarity of nerve grafts does not interfere with axon growth. Our goal was to investigate whether axons can regenerate in a retrograde fashion within sensory pathways and then extend into motor pathways, leading to muscle reinnervation. METHODS: Fifty-four rats were randomized into four groups. In Group 1, the ulnar nerve was connected end-to-end to the superficial radial nerve after neurectomy of the radial nerve in the axilla. In Group 2, the ulnar nerve was connected end-to-end to the radial nerve distal to the humerus; the radial nerve then was divided in the axilla. In Group 3, the radial nerve was divided in the axilla, but no nerve reconstruction was performed. In Group 4, the radial nerve was crushed in the axilla. Over 6 months, we behaviorally assessed the recovery of toe spread in the right operated-upon forepaw by lifting the rat by its tail and lowering it onto a flat surface. Six months after surgery, rats underwent reoperation, nerve transfers were tested electrophysiologically, and the posterior interosseous nerve (PIN) was removed for histological evaluation. RESULTS: Rats in the crush group recovered toe spread between 5 and 8 days after surgery. Rats with nerve transfers demonstrated electrophysiological and histological findings of nerve regeneration but no behavioral recovery. CONCLUSIONS: Ulnar nerve axons regrew into the superficial radial nerve and then into the PIN to reinnervate the extensor digitorum communis. We were unable to demonstrate behavioral recovery because rats cannot readapt to cross-nerve transfer.


Assuntos
Neurônios Motores , Nervos Periféricos , Ratos , Animais , Neurônios Motores/fisiologia , Nervos Periféricos/cirurgia , Regeneração Nervosa/fisiologia , Nervo Ulnar/cirurgia , Axônios/fisiologia , Vias Eferentes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...